Access panel fire resistance EI60 - System F6 BD

Access Panels
Access panel fire resistance EI60 - System F6 BD

  • Aluminium frame, for ceilings

  • Cladding 30 mm (2 x 15 mm)

On request special sizes can be manufactured in your desired size.

* Required Fields

€0.00

Questions regarding Access panel fire resistance EI60 - System F6 BD ?

Product description:

The access panel consists of aluminium profiles with plasterboard inlay GKF 30 mm (2 x 15 mm). Both outer and inner frame of the access panel consist of four single frames, which are firmly connected due to a special welding process. The access panel is equipped with catchwire. In order to avoid accidents, this safety-system has to be secured after each opening. A joint of 2,5 mm is visible between outer frame and door leaf, which is equipped with a circumferential fire-resistant seal (foaming). The concealed touch latches open the access panel when pressure is applied to the flap on the spring loaded latch side.

Capabilities:
 In non-bearing plasterboard ceilings of the fire resistance class EI60:

  • EI60 with cladding 30 mm

 Tested in accordance with the "European Norm EN 1364-2".

Customized solutions:

Customized sizes can be produced in every dimension upon enquiry.

Installation video
Additional Information

Additional Information

Fire Protection Fire-Rated
usage plasterboard ceilings
System System F6
FS - Screwdriver operated four-square cam latchFS - Four-square lock with wrench and rosettego to product
PZ - Profilzylinder-Hebelschloss mit SchlüsselPZ - Profile cylindergo to product
Z - Round Cylinder Lock with KeyZ - Round-cylinder lock with wrenchgo to product
Measures

Standard sizes for plasterboard inlay 30 mm with fire resistance EI60

System F6 - EI60ABCDE
BD200200F300 200 200 30 28 40
BD300300F300 300 300 30 28 40
BD400400F300 400 400 30 28 40
BD500500F300 500 500 30 28 40
BD600600F300 600 600 30 28 40
Advantages

Particular advantages of our system:

  • Economical solution
  • Delivery at short notice on request
  • Quick and easy installation
  • Sophisticated solution
  • Flush installation in plasterboard ceilings
  • Fire-resistant layer on the reverse side is longer necessary

Request quote!

Please send me an offer without engagement per e-mail ...

... or call me later.

* Required Fields